NR ZAIM

AU Fechner,G.; Brinkmann,B.; Heckmann,M.

TI [Heart current density as the most important biological parameter of electrocution in the bathtub]

OT Herzstromdichte als wichtigster biologischer Parameter bei Stromexposition in der Badewanne

QU Beitrage zur Gerichtlichen Medizin 1990; 48: 335-8

PT journal article

AB The most important factor during electrocution in a bathtub is the amount of current flowing through a body, not the amount of voltage. A method of measurement is introduced which - under simulation of various electrical situations - provides the possibility to measure the current flowing through the heart and to determine it's direction and density in the tissue. Hereby a ranking of the different factors influencing electrocution can be set up.

AD Institut für Rechtsmedizin, Westfalischen Wilhelms-Universität Munster.

SP deutsch

PO Österreich

Autorenindex - authors index
Startseite Betäubung - home page Stunning

Copyright Ingrid Schütt-Abraham